| tag class name | Text | 100 | | | | Core |
| tag name | Text | | | | | Core |
| ISO currency code | Text | 3 | | | | equipment class |
| equipment actual installation date | Date | | | | | equipment class |
| equipment actual purchase date | Date | | | | | equipment class |
| equipment actual startup date | Date | | | | | equipment class |
| equipment class name | Text | 100 | | | | equipment class |
| equipment code | Text | 40 | | | | equipment class |
| equipment manufacturer serial number | Text | 50 | | | | equipment class |
| equipment price | Number | | | | | equipment class |
| equipment warranty end date | Date | | | | | equipment class |
| manufacturer company name | Text | 30 | | | | equipment class |
| model part name | Text | 100 | | | | equipment class |
| plant code | Text | 40 | | | | equipment class |
| purchase order issuer company name | Text | 30 | | | | equipment class |
| purchase order item number | Number | | | | | equipment class |
| purchase order number | Text | 50 | | | | equipment class |
| vendor company name | Text | 30 | | | | equipment class |
| ATEX category | Text | 40 | | | ATEX category | alternating current motor |
| ATEX explosive atmosphere | Text | 40 | | | ATEX explosive atmosphere | alternating current motor |
| ATEX group | Text | 40 | | | ATEX group | alternating current motor |
| bearing lubrication | Text | 40 | | | electric motor bearing lubrication | alternating current motor |
| bearing lubrication specification | Text | 40 | | | | alternating current motor |
| bearing operating life | Text | 40 | | | bearing operating life | alternating current motor |
| bearing type | Text | 40 | | | bearing type | alternating current motor |
| cold air temperature at rated power | Number | | | TEMP | | alternating current motor |
| cross section area | Number | | | SURFAC | | alternating current motor |
| current at lower limit continuous operating speed at maximum torque | Number | | | ECURR | | alternating current motor |
| current at upper limit continuous operating speed at maximum torque | Number | | | ECURR | | alternating current motor |
| declared locked-rotor current at 100% rated voltage | Number | | | ECURR | | alternating current motor |
| declared locked-rotor current at 80% rated voltage | Number | | | ECURR | | alternating current motor |
| declared locked-rotor torque at 100% rated voltage | Number | | | MOMFOR | | alternating current motor |
| declared locked-rotor torque at 80% rated voltage | Number | | | MOMFOR | | alternating current motor |
| design specification | Text | 40 | | | | alternating current motor |
| driven equipment | Text | 40 | | | | alternating current motor |
| dry weight | Number | | | MASS | | alternating current motor |
| efficiency | Number | | | RATIO | | alternating current motor |
| efficiency at 100% rated output | Number | | | RATIO | | alternating current motor |
| efficiency at 50% rated output | Number | | | RATIO | | alternating current motor |
| efficiency at 75% rated output | Number | | | RATIO | | alternating current motor |
| efficiency at lower limit continuous operating speed | Number | | | RATIO | | alternating current motor |
| efficiency at maximum continuous operating speed at maximum torque | Number | | | RATIO | | alternating current motor |
| efficiency at upper limit continuous operating speed at upper torque value | Number | | | RATIO | | alternating current motor |
| explosion protection concept | Text | 40 | | | | alternating current motor |
| explosion protection examination certificate number | Text | 40 | | | | alternating current motor |
| explosion protection gas group | Text | 40 | | | explosion protection gas group | alternating current motor |
| explosion protection material group | Text | 100 | | | explosion protection material group | alternating current motor |
| explosion protection notified body | Text | 40 | | | | alternating current motor |
| explosion protection temperature class | Text | 40 | | | explosion protection temperature class | alternating current motor |
| explosion protection zone | Text | 40 | | | zone | alternating current motor |
| external axial loading on the motor shaft end | Number | | | FORCE | | alternating current motor |
| external radial loading on the motor shaft end | Number | | | FORCE | | alternating current motor |
| fan impeller material | Text | 100 | | | fan impeller material | alternating current motor |
| first lateral critical speed | Number | | | ANGVEL | | alternating current motor |
| frame size | Text | 40 | | | | alternating current motor |
| full load current | Number | | | ECURR | | alternating current motor |
| grease specification | Text | 40 | | | | alternating current motor |
| heat exchanger tubing material specification | Text | 100 | | | heat exchanger tubing material specification | alternating current motor |
| hot air temperature at rated power | Number | | | TEMP | | alternating current motor |
| impulse voltage insulation class | Text | 40 | | | impulse voltage insulation class | alternating current motor |
| ingress protection | Text | 40 | | | ingress protection | alternating current motor |
| internal bearing clearance | Text | 40 | | | internal bearing clearance | alternating current motor |
| junction box cable entry size | Number | | | LENGTH | | alternating current motor |
| junction box cable entry type | Text | 40 | | | cable entry type | alternating current motor |
| locked-rotor power factor at 100% rated voltage | Number | | | RATIO | | alternating current motor |
| locked-rotor torque in % of full load torque at 100% of rated voltage | Number | | | RATIO | | alternating current motor |
| locked-rotor torque in % of full load torque at 80% of rated voltage | Number | | | RATIO | | alternating current motor |
| locked-rotor withstand time (hot/cold) at 100 % rated voltage | Number | | | TIME | | alternating current motor |
| locked-rotor withstand time (hot/cold) at 80 % rated voltage | Number | | | TIME | | alternating current motor |
| lower limit design pressure | Number | | | PRESS | | alternating current motor |
| lower limit design temperature | Number | | | TEMP | | alternating current motor |
| moment of inertia of the motor | Number | | | MOMINT | | alternating current motor |
| number of electrical phases | Number | | | COUNT | | alternating current motor |
| number of junction box cable gland entries | Number | | | COUNT | | alternating current motor |
| oil quantity for self-lubricated sleeve bearings | Number | | | VOLUME | | alternating current motor |
| power factor at 100% rated output | Number | | | RATIO | | alternating current motor |
| power factor at 50% rated output | Number | | | RATIO | | alternating current motor |
| power factor at 75% rated output | Number | | | RATIO | | alternating current motor |
| power factor at lower limit continuous operating speed | Number | | | RATIO | | alternating current motor |
| power factor at upper limit continuous operating speed | Number | | | RATIO | | alternating current motor |
| pull-up torque | Number | | | MOMFOR | | alternating current motor |
| ramp-up time to minimum speed | Number | | | TIME | | alternating current motor |
| rated breakdown torque | Number | | | MOMFOR | | alternating current motor |
| rated current | Number | | | ECURR | | alternating current motor |
| rated frequency | Number | | | FREQU | | alternating current motor |
| rated output power | Number | | | POWER | | alternating current motor |
| rated power consumption | Number | | | POWER | | alternating current motor |
| rated power factor (lagging) | Number | | | RATIO | | alternating current motor |
| rated speed | Number | | | ANGVEL | | alternating current motor |
| rated speed at 1/1 load | Number | | | ANGVEL | | alternating current motor |
| rated torque | Number | | | MOMFOR | | alternating current motor |
| rated torque at 1/1 load | Number | | | MOMFOR | | alternating current motor |
| rated voltage | Number | | | VOLTAG | | alternating current motor |
| re-greasing interval | Number | | | TIME | | alternating current motor |
| service factor | Number | | | RATIO | | alternating current motor |
| starting current | Number | | | ECURR | | alternating current motor |
| tE time at 80 % voltage | Number | | | TIME | | alternating current motor |
| tE time at rated voltage | Number | | | TIME | | alternating current motor |
| temperature rise class | Text | 40 | | | temperature rise class | alternating current motor |
| thermal insulation class | Text | 40 | | | electrical insulation class | alternating current motor |
| total weight | Number | | | MASS | | alternating current motor |
| type of electric motor | Text | 40 | | | type of electric motor | alternating current motor |
| upper limit allowable vibration on load at rated output | Text | 40 | | | | alternating current motor |
| upper limit cooling water flow rate | Number | | | VOLFLO | | alternating current motor |
| upper limit declared motor sound power level at full load | Number | | | SOUND | | alternating current motor |
| upper limit declared motor sound power level at no-load | Number | | | SOUND | | alternating current motor |
| upper limit design pressure | Number | | | PRESS | | alternating current motor |
| upper limit design temperature | Number | | | TEMP | | alternating current motor |
| upper limit permissible starting time at 100% rated voltage | Number | | | TIME | | alternating current motor |
| upper limit permissible starting time at 80% rated voltage | Number | | | TIME | | alternating current motor |
| upper limit sound pressure level at no load | Number | | | SOUND | | alternating current motor |
| upper limit sound pressure level at no load at maximum continuous speed | Number | | | SOUND | | alternating current motor |
| upper limit sound pressure level at rated load | Number | | | SOUND | | alternating current motor |
| upper limit sound pressure level within the load envelope | Number | | | SOUND | | alternating current motor |
| voltage at lower limit continuous operating speed | Number | | | VOLTAG | | alternating current motor |
| voltage at upper limit continuous operating speed at maximum torque | Number | | | VOLTAG | | alternating current motor |