CFIHOS-40000110
Specify the gas group classification of the physical object in accordance with IEC/EN 60079-20
CFIHOS-40000612
Specify for purposes of testing, approval, and area classification, various air mixtures (not oxygen-enriched) grouped in accordance with 5006(A) and (B)
CFIHOS-40000111
The name of the nationally accredited approval body that has issued the examination certificate for the physical object
CFIHOS-40000112
Specify the temperature classification of the physical object in accordance with CENELEC EN50014
CFIHOS-40000113
Specify the hazardous zone in which the functional or physical object is expected to operate
CFIHOS-40000663
An indicator that an equipment has been classified as safe for use in hazardous areas
CFIHOS-40000862
The maximum anticipated axial loading on the shaft end
CFIHOS-40000613
Is a material specification for a coating on the outside of the equipment or component
CFIHOS-40000653
Specify the external corrosion protection type
CFIHOS-40000114
The type of insulation of a functional or physical object
CFIHOS-40000115
Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold
CFIHOS-40000116
The pressure at which a functional or physical object is expected to operate normally
CFIHOS-40000117
Is a temperature that occurs during operation or under which an object is supposed to operate
CFIHOS-40000861
The maximum anticipated radial loading on the shaft end for belt driven loads
CFIHOS-40000118
The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity
CFIHOS-40000119
The highest pressure at which a functional or physical object is designed for
CFIHOS-40000120
Specifies if the extraction of the steam is controlled with a valve, or left uncontrolled
CFIHOS-40000959
Specify if facility to remotely test withdrawn functional units are required
CFIHOS-40000695
Specify the factory location in Latitude and Longitude coordinates using decimal degrees
CFIHOS-40000580
The position to which the valve closure member moves when the actuating energy source fails
CFIHOS-40001390
Is a possessed aspect being a role of the substance of an artefact when used to construct the artefact from Therefore the substance should be in a solid state at the conditions at which the artefact exists
CFIHOS-40000712
Is a subtype of fan
CFIHOS-40000635
Existence of more than one means for performing the required function of an item Also known as redundancy in Redundancy in IEC and IEC 60050-192:2015
CFIHOS-40001335
Specify if fine balancing above rated speed is required
CFIHOS-40000121
Is an area located on a surface