target LOD

Text

Property Information
Details and background about this property.
Description
Length
Unit of Measure
Picklist
Equipment
Equipment that requires this property.

A flow transmitter specially designed to convert the signal from a positive displacement flow meter into a standardized electrical output signal.

An analysing instrument intended to determine the pour point of a fluid, i.e. the lowest temperature at which an oil or other liquid will pour under given conditions.

tag class

An electric cable intended for transmission of electric power.

tag class

A device that removes voltage spikes from an AC or DC electrical supply.

A physical object intended to supply electric power according to specified levels and tolerances.

Is a type of valve used in fire protection systems that controls the water supply such that water is released into the piping only in the event of a fire signal, preventing accidental water damage.

A detecting element intended to sense pressure.

A gauge intended to measure and display a representation of a measured pressure.

A regulator that is controlling/regulating the pressure in a system.

A gas flow damper that is used to relieve built-up pressure in a duct system to prevent damage to HVAC equipment.

A fluid regulator that relieves pressure from an enclosed space when the pressure reaches a predetermined value.

A functional switch that (usually) turns an electrical circuit on or off when the pressure level reaches a pre-set value.

A signal converter that is intended to convert a pressure input signal to DC output signal.

A transmitter that is producing a standardized output signal dependent of a received input signal from a pressure element.

A pressure relief valve that is intended to release excess pressure or admit pressure to prevent a vacuum forming when filling or emptying a pipeline or tank.

A non-corrugated plate heat exchanger that has flat plates with chemically etched flow passages which are diffusion bonded together into blocks.

Is a facilty for measure & control, including the main plant computerized operational system, where all process, utility and off site activities are monitored. The system may be located in the main control room. (e.g. PLC Programmable logic controller, DCS distributed control system, ENMC Electrical Network Monitoring and Control system).

A nozzle intended to enable transfer of process material.

A measuring relay that, either solely or in combination with other relays, is a constituent of a protection equipment.

A survival suit (or more specifically an immersion survival suit), is a special type of waterproof dry suit that protects the wearer from hypothermia from immersion in cold water, after abandoning a sinking or capsized vessel, especially in the open ocean

A detecting element that is intended to sense proximity.

A position switch that is operated without mechanical contact with the moving part.

A pressure vessel located in both pump- and compressor piping systems in order to reduce residual pulsation fluctuations, as a result of discontinue operation effects, within an allowable level specified.

Registers