t_explosion protection temperature class

Text

Property Information
Details and background about this property.
Description
Specify the temperature classification of the physical object in accordance with CENELEC EN50014
Length
Unit of Measure
Picklist
Equipment
Equipment that requires this property.

A control switch that is operated by a person.

A mechanical controller that is intended to position a given item in accordance with a received input signal.

A switchgear and controlgear that houses motor starters to control electric motors.

An operated valve that is opened and closed with a motor.

An analyser giving as output a signal that represents more than one physical properties of the analysed substance.

A flow meter for the metering a mixture of two or more fluid phases.

A valve not designed to regulate flow (e.g. on/off). A valve with multiple orifices or flow-restriction device to control fluid flow. Includes an actuator that needs auxiliary power to operate.

A valve not designed to regulate flow (e.g. on/off). A multi port valve which has the possibility of multiple distinct paths for flow through it. Includes an actuator that needs auxiliary power to operate.

A needle valve that is equipped with an actuator that manipulates a stream of fluid in the response to a signal from an external sensing element and with input of energy from an external source.

A circuit-breaker in which the contacts open and close in oil.

A mist detector that is intended to detect oil mist.

an element designed to measure an oxidation reduction potential (ORP).

tag class

One-way communications device in which the intended receiver is alerted to receive a message or return a phone call.

tag class

An internal combustion engine that is an induction compression ignition exhaust engine which ignites a petrol air mixture with an electric spark.

tag class

An analysing instrument intended to measure, indicate and/or produce a signal which represents the measured alkalinity / acidity in a fluid or matter.

tag class

an element designed to measure pH (potential of Hydrogen).

tag class

A detector that is intended to detect a pig inside the pipeline or pig receiver.

A transmitter intended to detect a pig passage and transmit a signal representing the measured value.

A differential pressure flow meter utilizing a pitot tube (a probe with an open tip) that is inserted into the flow field.

A control valve that is also a plug valve and an actuated valve.

An actuator that is intended to be operated by pneumatic power.

A mechanical controller that is using pneumatic components to execute its function.

A pilot switch the actuating system of which is operated by a moving part of a machine, when this part reaches a predetermined position.

A transmitter that is producing a standardized output signal dependent of a received input signal from a position detector.

Elements like impellers rotating by the pressure of the fluid in a closed conduit to measure the flow of a liquid.