explosion protection temperature class

Text

Property Information
Details and background about this property.
Description
Specify the temperature classification of the physical object in accordance with CENELEC EN50014
Length
40
Unit of Measure
Synonyms
  • CFIHOS ID
    CFIHOS-40000112
Equipment
Equipment that requires this property.
equipment class

A functional switch that (usually) turns an electrical circuit on or off when the pressure level reaches a pre-set value.

A functional switch that (usually) turns an electrical circuit on or off when the pressure level reaches a pre-set value.

A signal converter that is intended to convert a pressure input signal to DC output signal.

A signal converter that is intended to convert a pressure input signal to DC output signal.

A transmitter that is producing a standardized output signal dependent of a received input signal from a pressure element.

A non-corrugated plate heat exchanger that has flat plates with chemically etched flow passages which are diffusion bonded together into blocks.

Is a facility for measure & control, including the main plant computerized operational system, where all process, utility and off site activities are monitored. The system may be located in the main control room. (e.g. PLC Programmable logic controller, DCS distributed control system, ENMC Electrical Network Monitoring and Control system).

Is a facility for measure & control, including the main plant computerized operational system, where all process, utility and off site activities are monitored. The system may be located in the main control room. (e.g. PLC Programmable logic controller, DCS distributed control system, ENMC Electrical Network Monitoring and Control system).

equipment class

A measuring relay that, either solely or in combination with other relays, is a constituent of a protection equipment.

A measuring relay that, either solely or in combination with other relays, is a constituent of a protection equipment.

equipment class

A detecting element that is intended to sense proximity.

A detecting element that is intended to sense proximity.

equipment class

A position switch that is operated without mechanical contact with the moving part.

Is an alarm system.

tag class

A physical object that adds or removes mechanical energy to a fluid, either constantly or periodically.

equipment class

A manual control switch that is intended to switch when you push or touch the button.

tag class

A manual control switch that is intended to switch when you push or touch the button.

equipment class

A physical object for detecting the presence of objects at a distance, or ascertaining their position or motion, by transmitting short radio waves and detecting or measuring their return after being reflected.

tag class

A physical object for detecting the presence of objects at a distance, or ascertaining their position or motion, by transmitting short radio waves and detecting or measuring their return after being reflected.

equipment class

An element intended to determine a level based on high frequency electromagnetic waves.

An element intended to determine a level based on high frequency electromagnetic waves.

A level transmitter that is producing a standardized electrical output signal based on the input signal from a radar type level sensor.

A level transmitter that is producing a standardized electrical output signal based on the input signal from a radar type level sensor.

tag class

A radio transmitter, usually non-directional, that emits identifiable signals intended for radio direction-finding.

equipment class

A transceiver which has the methods of signalling through space, without connecting wires.