| HXT lower crown plug pressure rating | The lower crown plug pressure rating | Number |
| HXT upper crown plug pressure rating | The upper crown plug pressure rating | Number |
| VXT other tubing plug pressure rating | The VXT tubing plug or other plug pressure rating | Number |
| VXT tubing hanger annulus bore plug pressure rating | The VXT TH annulus bore plug pressure rating | Number |
| VXT tubing hanger production bore plug pressure rating | The VXT TH production bore plug pressure rating | Number |
| alternative design differential pressure | The differential pressure at which a functional or physical object is designed for in alternate conditions | Number |
| alternative operating differential head pressure | The rated differential pressure head at which a functional or physical object is expected to operate in alternate conditions | Number |
| alternative operating pressure | The rated pressure at which a functional or physical object is expected to operate in alternate conditions | Number |
| average ambient operating pressure at equipment location | The average ambient pressure at the plant's location | Number |
| bottom section lower limit operating pressure | Is a pressure that is a minimum possible or allowed or occurring or required | Number |
| bottom section normal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| burst pressure | A pressure that is the pressure that causes something to burst | Number |
| coil normal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| coil upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| cold differential test pressure | Is the pressure at which the pressure relief valve is adjusted to open on the bench It includes corrections for back pressure and/or temperature | Number |
| cold side maximum allowable working pressure new and cold | Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold | Number |
| cold side normal operating inlet pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| cold side normal operating outlet pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| cold side test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| cold side upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| constant back pressure | A back pressure that does not change under any conditions of operation | Number |
| external maximum allowable working pressure new and cold | Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold | Number |
| external operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| external test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| external upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| hot side maximum allowable working pressure new and cold | Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold | Number |
| hot side normal operating inlet pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| hot side normal operating outlet pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| hot side test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| hot side upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| hydrostatic test pressure | A test pressure applicable when using water to establish the test pressure | Number |
| intermediate section lower limit operating pressure | Is a pressure that is a minimum possible or allowed or occurring or required | Number |
| intermediate section normal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| internal maximum allowable working pressure new and cold | Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold | Number |
| internal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| internal test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| internal upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| jacket normal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| lmrp pressure connector pressure rating | Specify the pressure rating for the lower marine riser package connector | Number |
| lower limit allowable pressure | The pressure which is the lowest allowed | Number |
| lower limit design pressure | The lowest pressure at which a functional or physical object is designed | Number |
| lower limit dynamic sealing pressure | The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally | Number |
| lower limit operating discharge pressure | The discharge pressure which is the lowest pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating extraction steam pressure | The pressure which is the lowest extraction steam pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating heating steam inlet pressure | The pressure which is the lowest heating steam inlet pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating heating steam pressure | The pressure which is the lowest heating steam pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating inlet pressure | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its inlet connection | Number |
| lower limit operating inlet steam pressure | The pressure which is the lowest inlet steam pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating inlet steam pressure for auxiliary driver | The pressure which is the lowest inlet steam pressure for the auxiliary driver at which a functional or physical object is expected to operate | Number |
| lower limit operating inlet steam pressure for starter | The pressure which is the lowest inlet steam pressure for the starter at which a functional or physical object is expected to operate | Number |
| lower limit operating inlet steam pressure injection system | The temperature which is the lowest temperature at which a functional or physical object is expected to operate at its inlet steam for the steam injection system | Number |
| lower limit operating instrument air pressure | The pressure which is the lowest instrument air pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating outlet pressure | The pressure which is the lowest pressure at which a functional or physical object is expected to operate at its outlet connection | Number |
| lower limit operating outlet steam pressure | The pressure which is the lowest outlet steam pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating pressure | A pressure which is the lowest pressure at which a functional or physical object is expected to operate | Number |
| lower limit operating suction pressure | The suction pressure which is the lowest pressure at which a functional or physical object is expected to operate | Number |
| lower limit static sealing pressure | The lowest dynamic viscosity of the fluid in liquid phase at which a functional or physical object is expected to operate normally | Number |
| lower limit vapour pressure | A vapour pressure which is the lowest vapour pressure at which a functional or physical object is expected to operate | Number |
| lower upper operating instrument air pressure | The pressure which is the highest instrument air pressure at which a functional or physical object is expected to operate | Number |
| maximum allowable working pressure new and cold | Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold | Number |
| maximum back pressure | Is a back pressure that is maximally occurring | Number |
| maximum burst pressure | Is a burst pressure that is a upper tolerance burst pressure for a rupture disk | Number |
| minimum burst pressure | Is a burst pressure that is a lower tolerance pressure for a rupture disk | Number |
| normal operating cooling water pressure | The pressure at which a functional or physical objects cooling water is expected to operate | Number |
| normal operating differential pressure | The differential pressure at which a functional or physical object is expected to operate normally | Number |
| normal operating extraction steam pressure | The pressure which is the extraction steam pressure at which a functional or physical object is expected to operate normally | Number |
| normal operating inlet gas pressure for power turbine | The pressure at which a functional or physical object is expected to operate normally with its inlet gas to the power turbine | Number |
| normal operating inlet pressure | An inlet pressure at which a functional or physical object is expected to operate normally | Number |
| normal operating inlet steam pressure | The pressure at which a functional or physical object is expected to operate normally at its inlet steam | Number |
| normal operating inlet steam pressure auxiliary driver | The pressure at which a functional or physical object is expected to operate normally at its inlet steam for the auxiliary driver | Number |
| normal operating inlet steam pressure heating device | The pressure at which a functional or physical object is expected to operate normally at its inlet steam for the heating device | Number |
| normal operating inlet steam pressure injection system | The pressure at which a functional or physical object is expected to operate normally at its inlet steam for the steam injection system | Number |
| normal operating inlet steam pressure starter | The pressure at which a functional or physical object is expected to operate normally at its inlet steam for the starter | Number |
| normal operating outlet gas pressure for power turbine | The pressure at which a functional or physical object is expected to operate normally with its outlet gas of the power turbine | Number |
| normal operating outlet pressure | The pressure at which a functional or physical object is expected to operate normally at its outlet connection | Number |
| normal operating outlet steam pressure | The pressure at which a functional or physical object is expected to operate normally at its outlet steam | Number |
| normal operating outlet steam pressure auxiliary driver | The pressure at which a functional or physical object is expected to operate normally at its outlet steam for the auxiliary driver | Number |
| normal operating outlet steam pressure heating device | The pressure at which a functional or physical object is expected to operate normally at its outlet steam for the heating device | Number |
| normal operating outlet steam pressure starter | The pressure at which a functional or physical object is expected to operate normally at its outlet steam for the starter | Number |
| normal operating pressure | A pressure at which a functional or physical object is expected to operate normally | Number |
| normal operating pressure drop | A pressure drop at which a functional or physical object is expected to operate normally | Number |
| normal operating suction pressure | The normal suction pressure at which a functional or physical object is expected to operate | Number |
| normal operating vapour pressure | A vapour pressure at which a functional or physical object is expected to operate normally | Number |
| pump bowl maximum allowable working pressure | The pump bowl MAWP | Number |
| pump column maximum allowable working pressure | The pump column MAWP | Number |
| pump discharge head maximum allowable working pressure | The pump discharge head MAWP | Number |
| pump suction barrel or can maximum allowable working pressure | The pump suction barrel or can MAWP | Number |
| rated discharge pressure | The discharge pressure to which an installed item is rated | Number |
| rated inlet pressure | The pressure to which an installed item is rated | Number |
| rated operating differential head pressure | The differential pressure at which a functional or physical object is expected to operate normally | Number |
| rated operating differential pressure | The rated differential pressure at which a functional or physical object is expected to operate | Number |
| rated operating suction pressure | The rated suction pressure at which a functional or physical object is expected to operate | Number |
| relief valve set pressure | The pressure at which a functional or physical object is activated | Number |
| set pressure | A pressure at which an object is activated | Number |
| settle out pressure | The highest pressure which a functional or physical object will experience when not running and after equilibrium has been reached | Number |
| shell hydrostatic test pressure - field | Is a test pressure applicable when using water to establish the test pressure | Number |
| shell hydrostatic test pressure - shop | Is a test pressure applicable when using water to establish the test pressure | Number |
| shell normal external operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| shell normal internal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| shell side normal operating inlet pressure | An inlet pressure at the shell side at which a functional or physical object is expected to operate normally | Number |
| shell test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| shell upper limit allowable pressure | The pressure which is the highest allowed for the shell | Number |
| shell upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| steam drum relief valve set pressure | The pressure at which a functional or physical object is activated | Number |
| superheater relief valve set pressure | The pressure at which a functional or physical object is activated | Number |
| test pressure | A pressure to which an object should be subjected to test for leakage and structural integrity | Number |
| top section lower limit operating pressure | Is a pressure that is a minimum possible or allowed or occurring or required | Number |
| top section normal operating pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| tube hydrostatic test pressure - field | Is a test pressure applicable when using water to establish the test pressure | Number |
| tube hydrostatic test pressure - shop | Is a test pressure applicable when using water to establish the test pressure | Number |
| tube side normal operating inlet pressure | The pressure at which a functional or physical object is expected to operate normally | Number |
| tube test pressure | The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity | Number |
| tube upper limit allowable pressure | The pressure which is the highest allowed for the tube(s) | Number |
| tube upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| upper limit allowable pressure | The pressure which is the highest allowed | Number |
| upper limit design cooling water inlet pressure | The pressure which is the highest cooling water inlet pressure at which a functional or physical object is designed for | Number |
| upper limit design cooling water pressure | The pressure which is the highest cooling water pressure at which a functional or physical object is designed for | Number |
| upper limit design pressure | The highest pressure at which a functional or physical object is designed for | Number |
| upper limit dynamic sealing pressure | The highest dynamic sealing pressure at which a functional or physical object is expected to operate normally | Number |
| upper limit operating differential pressure | The differential pressure which is the highest differential pressure at which a functional or physical object is expected to operate | Number |
| upper limit operating discharge pressure | The discharge pressure which is the highest pressure at which a functional or physical object is expected to operate | Number |
| upper limit operating extraction steam pressure | The pressure which is the highest extraction steam pressure at which a functional or physical object is expected to operate | Number |
| upper limit operating heating steam pressure | The pressure which is the highest heating steam pressure at which a functional or physical object is expected to operate | Number |
| upper limit operating inlet pressure | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection | Number |
| upper limit operating inlet steam pressure | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet steam | Number |
| upper limit operating inlet steam pressure auxiliary driver | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet steam for the auxiliary driver | Number |
| upper limit operating inlet steam pressure heating device | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet steam for the heating device | Number |
| upper limit operating inlet steam pressure injection system | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet steam for the steam injection system | Number |
| upper limit operating inlet steam pressure starter | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet steam for the starter | Number |
| upper limit operating outlet pressure | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet connection | Number |
| upper limit operating outlet steam pressure | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its outlet steam | Number |
| upper limit operating pressure | A pressure which is the highest pressure at which a functional or physical object is expected to operate | Number |
| upper limit operating suction pressure | The pressure which is the highest pressure at which a functional or physical object is expected to operate at its inlet connection | Number |
| upper limit static sealing pressure | The highest static sealing pressure at which a functional or physical object is expected to operate normally | Number |
| upper limit vapour pressure | A vapour pressure which is the highest vapour pressure at which a functional or physical object is expected to operate | Number |
| vacuum pressure | Is a pressure below atmospheric pressure | Number |
| vapour pressure at rated temperature | The vapour pressure rated temperature to which an installed item is rated | Number |
| variable back pressure | A back pressure that varies due to changes in operation of one or more pressure relief valves connected into a common discharge header | Number |