Properties
All the properties in one place.
All the properties in one place.
CFIHOS-40001159
Specify where heat tracing and insulation is to be applied
CFIHOS-40000154
Is a subtype of tracing
CFIHOS-40001160
Specify who is responsible for supplying heat tracing
CFIHOS-40000697
The area that is available for heat transfer
CFIHOS-40000155
Is a number of items where each item is a tube
CFIHOS-40001240
Specify if a heating jacket is required
CFIHOS-40001131
Specify the heating medium
CFIHOS-40001162
Is a specification which describes the heating tracing
CFIHOS-40000496
A distance from the bottom to the top of something standing upright
CFIHOS-40000156
Specify if the functional or physical object is equipped with a helper driver, to accelerate the functional or physical object into self sustaining speed and remain coupled during operation to provide supplementary shaft power
CFIHOS-40000157
The capacitance presented to sources such as: harmonics, switching surges and transients
CFIHOS-40000907
The hot air temperature of the heat exchanger at rated power
CFIHOS-40000158
Specify if the functional or physical object has hot oil flushing functionality
CFIHOS-40000159
The name of the product in liquid or gas phase
CFIHOS-40000160
Is an allowable operating pressure that is the maximum pressure to which a container is allowed to be exposed during operating conditions when the item is new and cold
CFIHOS-40000161
Is a temperature that is the lowest at which a significant load can be applied Typically applied to a pressure vessel Defined by the ASME Code, Section VIII, Division 1, paragraph UG-20 (see Section 3)
CFIHOS-40000162
The pressure at which a functional or physical object is expected to operate normally
CFIHOS-40000617
The temperature at which a functional or physical object is expected to operate normally at its inlet connection for the hot side
CFIHOS-40000618
The mass flow rate at the hot side at which a functional or physical object is expected to operate normally
CFIHOS-40000163
The pressure at which a functional or physical object is expected to operate normally
CFIHOS-40000619
The temperature at which a functional or physical object is expected to operate normally at its outlet connection for the hot side
CFIHOS-40000164
Is a number of items where each item is a tube pass
CFIHOS-40000698
A drop in temperature that is acceptable at hot side
CFIHOS-40000165
The medium used for testing purpose
CFIHOS-40000166
The pressure to which a functional or physical object should be subjected to test for leakage and structural integrity